Product description
Model No.: PMDT 9800
PMDT 9800 Immunofluorescence Quantitative Analyzer is an analyzer for processing and analysis of PMDT test kits including markers for cardiovascular diseases, renal diseases, inflammation, fertility, diabetes mellitus, bone metabolism, tumor, and thyroid, etc. PMDT 9800 is used to measure concentration of biomarkers in human whole blood, serum, plasma or urine samples. The results can be used as an aid in clinical diagnosis of laboratory and point of care testing. It is applicable in Emergency, Clinical Lab, Outpatient, ICU, CCU, Cardiology, ambulance, operating room, wards, etc.
better designed POCT
★ steady structure for reliable results
★ auto alert to clean polluted cassettes
★ 9’screen, manipulation friendly
★ various ways of data exporting
★ full IP of testing system and kits
★ high-precision testing parts
★ independent testing tunnels
★ temperature & humidity auto-control
★ auto QC and self-checking
★ reacting time auto-control
★ auto-saving data
more accurate POCT
more intelligent POCT
★ high-throughput for gargantuan testing needs
★ testing cassettes auto-reading
★ various testing samples available
★ fitting in many emergency situations
★ capable to connect printer directly (special model only)
★ registered QC for all testing kits
★ registered QC for all testing kits
★ real-time monitoring of every tunnels
★ touch-screen instead of mouse and keyboard
★ AI chip for data management
application
Cardiology / Hematology / Nephrology / Gastroenterology /Respiratory
Anti-coagulation and Anti-thrombotic management in patients with coronary heart disease, myocardial infarction and cerebral infarction.
Bleeding and coagulation monitoring in in patients with hemophilia, dialysis, renal failure, liver cirrhosis and gastrointestinal bleeding
Orthopedics / Neurosurgery / General surgery / Alcohol / Transplantation / Oncology
Coagulation monitoring in pre-, intra- and post-operation management
Evaluation of heparin neutralization
Guide the Component Transfusion
Improve the blood coagulation detection methods
Identify the high-risk thrombosis / bleeding cases
Cardiology Department / Neurology Department / Vascular Surgery Department
Monitoring of Interventional therapy, thrombolytic therapy
Monitoring of individualized antiplatelet therapy
Rapid: Get result in 12 min for coagulation assessment
Early diagnosis: DIC and staging of hyperfibrinolysis
Monitoring of postpartum hemorrhage, amniotic fluid embolism, and obstetric DIC
Coagulation condition monitoring of of high risk pregnancy and Gynecological tumor patients to prevent bleeding and thrombosis
Evaluation of heparin neutralization
Diagnostic items list
Category |
Product name |
Full name |
Clinical solutions |
Cardiac |
sST2/NT-proBNP |
Soluble ST2/ N-Terminal Pro-Brain Natriuretic Peptide |
Clinical diagnosis of heart failure |
cTnl |
cardiac troponin I |
Highly sensitive and specific marker of myocardial damage |
NT-proBNP |
N-Terminal Pro-Brain Natriuretic Peptide |
Clinical diagnosis of heart failure |
BNP |
brainnatriureticpeptide |
Clinical diagnosis of heart failure |
Lp-PLA2 |
lipoprotein associated phospholipase A2 |
Marker of vascular inflammation and atherosclerosis |
S100-β |
S100-β protein |
Marker of blood–brain barrier (BBB) permeability and central nervous system(CNS) injury |
CK-MB/cTnl |
creatine kinase-MB/cardiac troponin I |
Highly sensitive and specific marker of myocardial damage |
CK-MB |
creatine kinase-MB |
Highly sensitive and specific marker of myocardial damage |
Myo |
Myoglobin |
Sensitive marker for heart or muscle injury |
ST2 |
soluble growth stimulation expressed gene 2 |
Clinical diagnosis of heart failure |
CK-MB/cTnI/Myo |
- |
Highly sensitive and specific marker of myocardial damage |
H-fabp |
Heart-type fatty acid-binding protein |
Clinical diagnosis of heart failure |
Coagulation |
D-Dimer |
D-dimer |
Diagnosis of coagulation |
Inflammation |
CRP |
C-reactive protein |
Evaluation of inflammation |
SAA |
serum amyloid A protein |
Evaluation of inflammation |
hs-CRP+CRP |
The high-sensitivity C-reactive protein +C-reactive protein |
Evaluation of inflammation |
SAA/CRP |
- |
Virus infection |
PCT |
procalcitonin |
Identification and diasnosis of bacterial infection, guiding the application of antibiotics |
IL-6 |
Interleukin- 6 |
Identification and diasnosis of inflammation and infection |
Renal Function |
MAU |
Microalbumininurine |
Risk evaluation of kidney disease |
NGAL |
neutrophil gelatinase associated lipocalin |
Marker of acute renal injury |
Diabetes |
HbA1c |
Hemoglobin A1C |
The best indicator to monitior the control of blood glucose of the diabetics |
Health |
N-MID |
N-MID OsteocalcinFIA |
Monitoring therapeutic treatments of Osteoporosis |
Ferritin |
Ferritin |
Prediction of Iron deficiency anemia |
25-OH-VD |
25-Hydroxy Vitamin D |
indicator of osteoporosis (bone weakness) and rickets (bone malformation) |
VB12 |
vitamin B12 |
Symptoms of vitamin B12 deficiency |
Thyroid |
TSH |
thyroid stimulating hormone |
Indicator for the diagnosis and treatment of hyperthyroidism and hypothyroidism and the study of the hypothalamic-pituitary-thyroid axis |
T3 |
Triiodothyronine |
indicators for the diagnosis of hyperthyroidism |
T4 |
Thyroxine |
indicators for the diagnosis of hyperthyroidism |
Hormone |
FSH |
follicle-stimulating hormone |
Assist in assessing ovarian health |
LH |
luteinizing hormone |
Assist in determining pregnancy |
PRL |
Prolactin |
For pituitary microtumor, reproductive biology study |
Cortisol |
Human Cortisol |
Adrenal cortical function diagnosis |
FA |
folic acid |
Prevention of fetal neural tube malformation, pregnant women/newborn nutrition judgment |
β-HCG |
β-human chorionic gonadotropin |
Assist in determining pregnancy |
T |
Testosterone |
Assist to evaluate the endocrine hormone situation |
Prog |
progesterone |
Diagnosis of pregnancy |
AMH |
anti-mullerian hormone |
Evaluation the fertility |
INHB |
Inhibin B |
Marker of remaining fertility and ovarian function |
E2 |
Estradiol |
The main sex hormones for women |
Gastric |
PGI/II |
Pepsinogen I, Pepsinogen II |
Diagnosis of gastric mucosa injury |
G17 |
Gastrin 17 |
Gastric acid secretion, gastric health indicators |
Cancer |
PSA |
|
Assist in the diagnosis of prostate cancer |
AFP |
alPhafetoProtein |
Marker of liver cancer serum |
CEA |
carcinoembryonic antigen |
Assist in the diagnosis of colorectal cancer, pancreatic cancer, gastric cancer, breast cancer, medullary thyroid cancer, liver cancer, lung cancer, ovarian cancer, urinary system tumors |
About POCT
POCT has emerged in recent years and has developed rapidly, mainly to meet the current market needs. Therefore, a fast, convenient, accurate and practical analyzer suitable for the diagnosis industry is designed, coupled with the current technology in electronic technology. Achieving the interconnection of information is the concept of our product design. This product is used for in vitro testing, and is widely used in central laboratories, outpatient/emergency laboratories, clinical departments and other medical service points (such as community medical points), physical examination centers, etc. of medical institutions. It is also suitable for scientific research laboratory testing. The original colloidal gold detection is based on visual judgment. Due to the impact of differences in human vision on clinical diagnosis, quantitative analysis of the results is achieved, which is truly fast and accurate. It replaces manual judgment with instrument analysis, realizes monitoring data summary report with the help of network, and can remotely diagnose and upgrade, which reduces human error, improves the speed of diagnosis and realizes centralized management of hospital information. This product uses an 8-inch touch screen as human-computer interaction, the screen display is clear, the touch is sensitive, and the test results can be automatically uploaded to the computer or network, which is convenient and practical. This product is an in vitro diagnostic instrument. It does not produce toxic and harmful substances that have an impact on the environment during operation. The materials used in the product are all recyclable. Fast and convenient to replace manual labor, wireless communication, remote diagnosis, remote upgrade, not only suitable for clinical diagnosis, improve detection efficiency and accuracy, but also convenient and fast because of joining the network.